A rented office's electricity is not automatically Scope 3. Start with the organisational consolidation approach used for the inventory, then examine the lease and control facts. Who receives the utility bill is evidence about the arrangement; it is not, by itself, the scope decision.
GHG Protocol's leased-assets FAQ explains that treatment depends on the consolidation approach and lease type. For a lessee applying operational control, an operating lease normally places fuel combustion in Scope 1 and purchased electricity in Scope 2. A lessee may exceptionally demonstrate that it lacks operational control and report the relevant emissions in Scope 3, with justification and disclosure. S1
Write the boundary decision before entering a factor
Confirm the consolidation approach already used across the organisation. Do not change it for one office because a landlord recharge is inconvenient. GHG Protocol's operational-control test concerns authority to establish and carry out operating policies; it does not require unilateral authority over every capital decision. S4 Ask finance and the operating owner to explain how the actual arrangement meets that test.
This article does not translate modern financial-reporting lease classifications into greenhouse-gas scopes or decide the legal meaning of a lease. Where those classifications are material, obtain an appropriately reviewed interpretation. The practical record below is a way to make the inventory decision explicit.
A completed fictional office record
Example LEASE-024 concerns a fictional company's office for July–September 2026. Its inventory applies operational control. The landlord receives the main utility invoice and recharges the tenant; a dedicated tenant meter records 9,000 kWh for the quarter. The following invented evidence pack makes the control decision reviewable. It represents no actual lease or legal assessment.
| Fictional evidence | What the reviewer checks |
|---|---|
| BND-01: company inventory policy | Operational control is the selected consolidation approach for every operation. |
| LEASE-24: operating-responsibility schedule | For this example, it assigns the tenant authority to set and implement operating policies throughout the leased suite; landlord approval is retained for structural alterations. |
| OPS-24: implemented office procedures | Tenant management sets office operating hours, equipment shutdown rules and maintenance arrangements, and staff follow those procedures. |
| DEC-24: inventory-owner conclusion | Read together, the agreement and actual operating arrangements support tenant operational control. The electricity invoice payer is not the deciding fact. |
These evidence examples are not a universal checklist that proves control. Permission to adjust a thermostat alone would not establish authority over an operation. If the contract and actual practice conflict, or a serviced-office provider retains the operating policies, hold the classification for review instead of copying this conclusion.
| Decision field | Completed fictional record |
|---|---|
| Reporting entity | Tenant company; office O-24 |
| Consolidation approach | Operational control, consistent with its inventory boundary policy |
| Control finding | Tenant controls operating policy for the leased suite; conclusion linked to fictional records BND-01, LEASE-24 and OPS-24 below |
| Invoice arrangement | Landlord pays supplier; tenant receives recharge and meter evidence |
| Energy record | 9,000 kWh consumed in the quarter; meter period matches lease occupancy |
| Classification outcome | Tenant's electricity included in Scope 2; no second entry for that electricity in Category 8 |
For arithmetic only, an invented factor of 0.20 kg CO2e/kWh produces 9,000 × 0.20 = 1,800 kg CO2e. That factor is not appropriate evidence for a real inventory. The example demonstrates the classification and units; it does not complete location-based and market-based reporting or validate a supplier's contractual electricity claim.
The landlord's payment of the bill does not make the consumed electricity disappear. GHG Protocol's Scope 2 guidance expressly addresses acquired energy in leased buildings where the tenant may not pay the electricity supplier directly. S3
What would change the classification?
Consider a separate hypothetical case in which a properly supported review concludes that the lessee does not have operational control, and the treatment under its chosen consolidation approach places the leased operation outside Scopes 1 and 2. Category 8 then covers relevant leased-asset operating emissions not already included in those scopes. S2 This is an alternative fact pattern, not permission to move the same 1,800 kg between columns to make Scope 2 look smaller.
For a lease covering only part of the reporting year, identify that period when gathering data. Category 8 guidance provides asset-specific, lessor-specific and average-data approaches; use the appropriate boundary and documented data available for the leased operation. S2 A missing dedicated meter is a data-quality issue to resolve, not proof that electricity is outside the inventory.
Three questions to settle before the close
- Has the scope decision been signed off by the owner of the inventory boundary, with the chosen consolidation approach and evidence recorded?
- Does the consumption record cover the same premises and period as the decision, including any changes of tenant or operating arrangement?
- Has the same electricity been excluded from duplicate entries in other scopes or leased-asset categories within this inventory?
Keep the landlord's inventory separate from the tenant's reconciliation. The fact that an amount appears in another organisation's reporting does not alone tell you that your own treatment is wrong. The immediate control is consistent categorisation within the reporting entity and transparent accounting boundaries.
Before closing the office's carbon record, attach a one-page boundary decision to the electricity evidence. If the decision remains unresolved, show that exception to the inventory owner rather than silently choosing Scope 3.