Not defensibly from mass alone. The same number of tonnes can produce different calculation results depending on the waste, its treatment and the emissions boundary of the factor. If the contractor supplies only a total, keep that mass in the record and identify the missing treatment evidence before producing a single emissions result.
GHG Protocol Category 5 includes third-party treatment and disposal of waste generated in operations. Its average-data method uses total mass, the proportion treated by each method and corresponding treatment factors. Waste-type-specific and supplier-specific methods are also available. S1 A total tonnage does not supply the missing proportions.
Ask for the information that changes the calculation
Request a reconciliation covering your organisation and reporting period: total collected mass, waste descriptions, treatment routes, treatment locations where relevant to factor selection, and the evidence supporting each route. If the contractor uses a site-wide allocation across several customers, ask how your share was calculated. Keep measured customer mass separate from allocated treatment estimates.
Do not treat an invoice label such as recycling service as proof of the final treatment split. Equally, do not demand unnecessary precision from a mixed-waste estimate: document what was measured, what was allocated and what remains unknown. Select the calculation method that the evidence can support.
A completed fictional record after one follow-up
Example WASTE-028 begins with a contractor reporting 10.0 tonnes collected in September 2026. A follow-up supports a treatment split for 8.0 tonnes; 2.0 tonnes remain unresolved. The example invents factors of 20 kg CO2e per tonne for Route R and 400 kg CO2e per tonne for Route L. They demonstrate arithmetic only and must not be used as real recycling or landfill factors.
| Record line | Evidence status | Illustrative calculation |
|---|---|---|
| 6.0 t, Route R: recycling treatment | Route supported in this fictional record | 6.0 × 20 = 120 kg CO2e |
| 2.0 t, Route L: landfill treatment | Route supported in this fictional record | 2.0 × 400 = 800 kg CO2e |
| 2.0 t, treatment unknown | No supported route yet | No confirmed treatment-emissions amount |
| 10.0 t total | Mass reconciled; treatment known for 80% | Known-route subtotal: 920 kg CO2e |
The mass adds up: 6 + 2 + 2 = 10 tonnes. The supported-route share is 8/10 = 80%, and the unresolved share is 20%. Neither percentage tells us that we have captured 80% of the emissions: the unknown portion could have a very different factor.
Use scenarios without disguising them as measured results
For an internal sensitivity check only, suppose the unresolved 2 tonnes used the fictional Route R factor. That would add 40 kg, producing 960 kg CO2e. If it used the fictional Route L factor, it would add 800 kg, producing 1,720 kg CO2e.
These are two explicitly assumed scenarios. The interval from 960 to 1,720 kg is not a confidence interval, a proven minimum-to-maximum range or the actual inventory result. Another waste composition, treatment or factor boundary could fall outside it. Taking the midpoint would create a precise-looking number without supplying the missing evidence.
| Decision field | Completed fictional entry |
|---|---|
| Calculation status | Incomplete: 920 kg known-route illustrative subtotal; 2.0 t unresolved |
| Reason | Treatment evidence missing for 20% of the mass |
| Sensitivity note | Two assumed scenarios: 960 or 1,720 kg; neither a reported actual total |
| Action owner | Waste contract manager to reconcile unresolved loads and document allocation method |
| Closure condition | Supported treatment data or a documented, suitable estimation method with uncertainty disclosure |
Check the factor boundary before accepting a negative result
A recycling factor can represent a different question from the treatment emissions belonging in a corporate inventory. GHG Protocol guidance keeps avoided-emissions claims from recycling separate from Scope 1, 2 and 3 totals; they are not deducted from the Scope 3 inventory. S1 Examine what a contractor's figure includes rather than copying a negative number into Category 5.
For a real record, retain the factor publisher, version, waste description, treatment, geography, units and included processes. Avoid mixing a factor for treatment operations with a life-cycle comparison that credits avoided virgin production. Wastewater and waste treated within the reporting organisation's own boundary may require separate treatment from this simplified third-party solid-waste example.
Your immediate output can be a useful exception record rather than an invented total. Reconcile the tonnes, quantify the unresolved share, assign the missing-evidence action and state exactly which result is still pending.
Prepared with AI-assisted research and drafting. Reviewed by: QSE Advisory experts.
Sources
This article is general information. Verify current requirements and seek qualified advice for your specific circumstances.
Reviewed by QSE Advisory experts
Every article is researched, sourced and checked before publishing.
Editorial standards →